Przewodnik zakupu wytrząsarek elektrodynamicznych wysokiej częstotliwości

Przewodnik zakupu wytrząsarek elektrodynamicznych wysokiej częstotliwości



High Frequency  Electrodynamic shakers Purchasing Guide

Selecting the right high frequency vibration test machine is crucial to meet the specific needs and requirements of your industry. This purchasing guide will provide you with detailed information and specific data to help you make an informed decision. It takes into consideration industry pain points, hotspots, and international standards. Please find below the detailed guide in Angielski.

Wymagane warunki testowania

Aby wybrać odpowiednią platformę elektryczną, ważne jest, aby podać następujące informacje dotyczące warunków testowania wibracji:
1. Zakres częstotliwości (w hercach, Hz) dla testu wibracji.
2. Magnitude of shaker test parameters such as acceleration (m/s² or g), displacement (mmp-p or p), velocity (m/s), or acceleration spectral density (PSD) values (g²/Hz or m²/s³).
3. Kierunek testu wibracyjnego: Niezależnie od tego, czy jest to jednoosiowy test pionowy, czy trzyosiowy (XYZ).
4. Wymiary (długość, szerokość, wysokość) i waga próbki do badań.
5. Masa próbki do badań (w kilogramach, kg).

Obliczanie wyboru platformy elektrycznej
Na podstawie maksymalnych wymiarów i wagi badanej próbki wybierz pionową platformę rozprężną.
The electric platform acts as the vibration source, and its working platform size is small, mainly used for fixture installation and expansion. Therefore, determine the size and weight of the expansion platform or fixture before the selection calculation. The main technical parameters of the vertical expansion platform are its dimensions, weight, and upper frequency limit. The maximum dimensions of the test specimen should be smaller than or equal to the expansion platform size, and the upper frequency limit of the vibration test should be smaller than or equal to the vertical expansion platform's upper frequency limit. Therefore, the dimensions and weight of the expansion platform can be determined based on the maximum dimensions and highest test frequency of the test specimen. The following data is for reference purposes only, as the specifications of the vertical platform or horizontal slide platform in different vibration equipment configurations may vary due to the different materials used.

Wybierz poziomą platformę przesuwną w oparciu o kierunek testu wibracyjnego

Jeśli próba wibracyjna próbki testowej jest wymagana tylko w kierunku pionowym, wystarczy pionowa platforma rozprężna. Jednak w przypadku ogólnych badań wibracyjnych, które wymagają trójosiowych (osiowych) drgań badanej próbki, stała pozycja podczas badania wibracyjnego powinna w jak największym stopniu symulować stałą pozycję próbki do badań w stanie roboczym lub transportowym.
Jeśli nie ma określonych wymagań dotyczących pozycji montażowej dla próbki do badań w stanie roboczym lub transportowym, tj. jeśli zmiana środka ciężkości próbki do badań poprzez odwrócenie jej nie wpływa na jej działanie, wówczas trójosiowe wibracje próbki do badań można osiągnąć poprzez ustalenie kierunku wibracji platformy elektrycznej i zmianę środka ciężkości próbki do badań. W takim przypadku wymagana jest tylko pionowa platforma rozprężna. Jednak w przypadku dużych próbek testowych wystarczająca jest pozioma platforma przesuwna ze względu na wymagany duży rozmiar platformy elektrycznej.
Jeśli istnieją określone wymagania dotyczące pozycji montażowej dla próbki do badań w stanie roboczym lub transportowym, tj. jeśli zmiana środka ciężkości próbki do badań poprzez odwrócenie jej wpływa na jej działanie, wówczas należy zmienić kierunek wibracji platformy elektrycznej, aby uzyskać trzyosiowe wibracje próbki do badań przy zachowaniu niezmienionego środka ciężkości próbki do badań. W takim przypadku wymagana jest zarówno pionowa platforma rozprężna, jak i poziomy stół wibracyjny.
The technical specifications of the SC series horizontal slip table produced by ALITETSING——JOEO are provided below for reference. The selection process for the horizontal slide platform is similar to that of the vertical expansion platform. Note: The higher the upper frequency limit, the higher the required rigidity coefficient and the heavier the platform components. The calculation for the maximum acceleration in vibration testing is as follows:

Warunki testu drgań sinusoidalnych są ogólnie podzielone na:
1) Constant Acceleration Swept Sine Test: f1--f2, Acceleration A1. In this test, the maximum acceleration within the frequency range from f1 to f2 is A1. The conversion formula for displacement D during swept frequency vibration is: D = A1×103/(2πf)2. Thus, the maximum displacement is D1MAX = A1×103/(2πf1)2.
2) Constant Velocity Swept Sine Test: f1--f2, Velocity V. The conversion formula between velocity and acceleration is: A = (2πf)V, where A is in m/s² and V is in m/s. Thus, the maximum acceleration is A2MAX = (2πf2)V. The conversion formula for displacement D during swept frequency vibration is: D = V×103/(2πf). Thus, the maximum displacement is D2MAX = V×103/(2πf1).
3) Constant Displacement Swept Sine Test: f1--f2, Displacement D. The conversion formula between displacement D and acceleration A is: A = (2πf)2D×10-3, where A is in m/s² and D is in mm. Thus, the maximum acceleration is A3MAX = (2πf)2D×10-3, and the maximum displacement is D.
4) Test sinusoidalny z wieloma segmentami ze stałym przyspieszeniem i stałym przemieszczeniem. Maksymalne przyspieszenie dla każdego segmentu oblicza się w sposób opisany powyżej, a następnie wybiera się maksymalną wartość spośród A1, A2MAX i A3MAX jako maksymalne przyspieszenie dla warunków badania. Podobnie, maksymalne przemieszczenie jest obliczane z D1MAX, D2MAX i D, a wartość maksymalna jest wybierana jako maksymalne przemieszczenie dla warunków testowych.

Obliczenie maksymalnego przyspieszenia drgań losowych jest następujące:
Dla warunków badania drgań losowych z danym zakresem częstotliwości, wartością gęstości widmowej i wartością przyspieszenia średniokwadratowego (ARMS), wartość ARMS jest maksymalnym wymaganym przyspieszeniem. Jeśli wartość ARMS nie zostanie podana, należy ją obliczyć osobno. Warunki testowe można wprowadzić do przyrządu do kontroli drgań losowych (oprogramowania) w celu obliczenia wartości średniego przyspieszenia kwadratowego ARMS i amplitudy drgań Drms.

1. Calculate the acceleration value a based on the user's specified requirements. The test conditions are as follows:
20-80Hz, 3 dB/oct; 80-350Hz, 0.04g²/Hz; 350-2000Hz, -3 dB/oct.

2. Kalkulacja jest następująca:
1) Dla widma rosnącego (nachylenie N1 dB/okt):
Gdzie m = N1/3.
 Then, F1 = 0.04×80[1-(20/80)²]/(1+1) = 1.5.
2) Dla płaskiego spektrum:
   F2 = P(f3 - f2) = 0.04×(350-80) = 10.8.
3) Dla widma malejącego (nachylenie -N2 dB/okt):
From F3 = 0.04×350[-ln(350/2000)] = 24.5.
The formula for a is a = √(F1 + F2 + F3).
Therefore, a = √(1.5 + 10.8 + 24.5) = 6.06g.

3. According to Newton's second law (F = ma), calculate the force F:
 F = (M1 + M2 + M3)×a,
 gdzie:
 M1 - Masa ruchomych części platformy elektrycznej (kg).
 M2 - Waga pionowej platformy rozprężnej, poziomej platformy przesuwnej lub uchwytu (kg).
 M3 - Maksymalna waga próbki do badań (kg).
 a - Maximum acceleration of the vibration test (m/s²).

Siła F powinna być mniejsza lub równa maksymalnej sinusoidalnej sile wzbudzenia platformy elektrycznej.
For random vibration, the force Frms is calculated as Frms = M×Arms and should be less than the rated random excitation force of the electric platform.

4. Potwierdzić, że maksymalne przemieszczenie platformy elektrycznej jest większe niż maksymalne przemieszczenie w warunkach badania. W przypadku drgań losowych średnia kwadratowa amplitudy Drms obliczona przez komputer powinna być mniejsza niż jedna trzecia amplitudy znamionowej platformy elektrycznej.

5. Wybierz przyrząd do kontroli sinusoidalnej lub przyrząd do kontroli drgań losowych w oparciu o określone warunki testowe. Jeśli istnieją parametry dla drgań losowych, należy wybrać przyrząd do kontroli drgań losowych.

Konkluzja

Wybierając tester drgań wysokiej częstotliwości, należy wziąć pod uwagę specyficzne wymagania Twojej branży, w tym warunki testowania, obliczenia wyboru platformy elektrycznej, obliczanie siły oraz potrzebę kontroli drgań sinusoidalnych lub losowych. Postępując zgodnie z tym przewodnikiem zakupów i biorąc pod uwagę szczegółowe specyfikacje i wymagania, możesz wybrać najbardziej odpowiedni tester drgań wysokiej częstotliwości dla swojej branży.

Należy pamiętać, że ten przewodnik zawiera szczegółowe informacje oparte na potrzebach branży, punktach bólu i międzynarodowych standardach. Zaleca się zapoznanie się z instrukcjami obsługi produktu i odpowiednimi specyfikacjami, aby upewnić się, że zakupiony sprzęt spełnia określone wymagania przed faktycznym użyciem.

Skontaktuj się z nami