Pięć czynników, które należy wziąć pod uwagę przy zakupie komór do testów środowiskowych

Pięć czynników, które należy wziąć pod uwagę przy zakupie komór do testów środowiskowych



Environmental test chambers, also known as temperature and humidity environment chamber, climate chamber, is commonly used in laboratories and factories for environmental simulation systems and devices. Environmental test chamber can simulate temperature, humidity, air pressure, light, vibration, corrosion and other different environmental conditions. The test chamber is usually composed of control system, heating system, refrigeration system, humidity control system, air pressure control system, lighting system, vibration system, corrosion system and so on. According to the test requirements, different environmental parameters can be selected for adjustment to simulate the required environmental conditions. There are many kinds of environment boxes. For people who are not familiar with environment boxes and who buy them for the first time, choosing environment boxes is a very headache. Therefore, through this article, I will help you to understand how to choose the right temperature and humidity environment room? In addition, if you want to know more about the standards and applications of temperature and humidity boxes, you can contact our company's technical staff. We will give you a satisfactory answer as soon as possible.

1. Wymogi dotyczące badań

Przede wszystkim konieczne jest zdefiniowanie typu produktu, parametrów testowych i norm testowych, aby wybrać komorę do badań środowiskowych, która spełnia wymagania testowe. Ważne jest, aby szczegółowo przeanalizować wymagania testowe przy wyborze odpowiedniej komory do badań środowiskowych dla swoich wymagań. Najpierw zastanów się, jaki rodzaj środowiska testujesz i czy panują w nim jakieś ekstremalne warunki, takie jak temperatura, wilgotność lub wysokość. Po drugie, należy wziąć pod uwagę swoją branżę, taką jak: przemysł produktów elektronicznych i elektrycznych: produkty elektroniczne i elektryczne muszą przejść przez niską temperaturę, wysoką temperaturę, cykl wysokiej temperatury, wpływ wysokiej i niskiej temperatury, mgłę solną, ciepło i wilgotność, wibracje, upadki i inne testy, aby ocenić ich niezawodność i trwałość w różnych środowiskach.

2. Wybór zakresu temperatur

Zakres komory testowej temperatury obcej wynosi zwykle -73 ~ + 177 °C lub -70 ~ 180 °C. Krajowi producenci produktów to głównie -80 ~ + 130 °C, -60 ~ + 130 °C, -40 ~ + 130 °C, wysoka temperatura do 150 °C. Te zakresy temperatur zwykle spełniają potrzeby większości krajowych, wojskowych i cywilnych testów temperatury.

3. Zakres wilgotności

Select the appropriate humidity range according to the test requirements. Some test chambers can simulate very high humidity (such as 95%RH or higher), while others are suitable for very dry environments (such as 0%RH) where the higher the temperature, the lower the relative humidity for the same absolute moisture content. For example, the absolute moisture content is 5g/kg, and when the temperature is 29℃, the relative humidity is 20%RH. When the temperature is 6°C, the relative humidity is 90% RH. When the temperature drops below 4℃ and the relative humidity exceeds 100%, condensation will occur in the box. The temperature index of environmental test chamber at home and abroad is generally 20~98%RH or 30~98%RH. If the constant temperature and humidity box does not have a dehumidification system, the temperature ranges from 60 to 98%. The chamber can only be used for high humidity tests, but it is much cheaper. It is important to note that the humidity indicator should be followed by the corresponding temperature range or minimum dew point temperature. Because relative humidity is directly related to temperature.

4. Dokładność kontroli

The control precision of environmental test chamber has important influence on the accuracy and reliability of test results. The appropriate control precision needs to be selected according to the test requirements. Usually, the more accurate the control, the higher the price of the equipment. The relative humidity deviation of environmental test chamber should be ±2%RH or ±3%RH. In order to meet the requirements of temperature control accuracy, the temperature fluctuation is generally less than ±0.2℃; otherwise, it is difficult to meet the requirements of humidity control accuracy

5. Prędkość wiatru

Zgodnie z odpowiednimi normami, podczas przeprowadzania testów środowiskowych, prędkość wiatru w skrzynce testowej temperatury i wilgotności powinna być mniejsza niż 1,7 m/s. Ale jeśli potrzeba szybkiej zmiany temperatury w komorze testowej i temperatury, wilgotności, wibracji i innych czynników kompleksowej komory testowej środowiskowej, przyspiesz natężenie przepływu powietrza krążącego w zbiorniku. Prędkość wiatru wynosi zwykle 2 ~ 3 m / s. W przypadku najbardziej ogólnych wymagań testowych prędkość wiatru w komorze do badań środowiskowych wynosi zwykle od 0,5 m/s do 2,5 m/s, a prędkość wiatru w tym zakresie może spełniać większość wymagań testowych. Na przykład w przypadku testowania produktów elektronicznych i elektrycznych typowy zakres prędkości wiatru wynosi od 0,5 m/s do 1,5 m/s; W przypadku testowania części samochodowych typowy zakres prędkości wiatru wynosi od 1,5 m/s do 2,5 m/s.